ETHERLINE® LAN 500 Cat.6A

Ethernet cable for Category 6A/ class EA -verified up to 500 MHz

Ethernet cable for Category 6A/ class EA -verified up to 500 MHz

CPR: Article number choice under www.lappkabel.com/cpr

Flame-retardantHalogen-freeInterference signals

Article number Article designationNumber of pairs and AWG per conductorCore diameter in mmOuter diameter mmColourCopper index (kg/km)Weight (kg/km)
PVC
2170960
ETHERLINE® LAN Cat.6A S/FTP 4x2xAWG234 x 2 x AWG23/11.287.3grey2452
2170961
ETHERLINE® LAN Cat.6A F/UTP 4x2xAWG234 x 2 x AWG23/11.097.4grey2452
LSZH
2170962
ETHERLINE® LAN Cat.6A F/FTP 4x2xAWG23 LSZH4 x 2 x AWG23/11.287.3orange2254
2170963
ETHERLINE® LAN Cat.6A F/UTP 4x2xAWG23 LSZH4 x 2 x AWG23/11.097.4orange2456

Benefits

  • LAN cables for structured building cabling according to EN 50173 and ISO/IEC 11801

Application range

  • Areas where the end device density is very high
  • For office wiring, administration and development buildings in the tertiary sector (floor wiring).
  • Cable length in tertiary area (horizontal area, floor) should not exceed a length of 100 m in accordance with the ISO/IEC 11801 and EN 50173 standards (90 m in cable duct + 10 m in working area)

Product features

  • Transfer of digital and analogue data signals
  • IEEE 802.3: 10/100/1000Base-T, 10GBase-T IEEE 802.5: ISDN; FDDI; ATM; cable sharing
  • Flame retardant acc. to IEC 60332-1-2

Norm references / Approvals

  • LAN Cat.6A cables from Lapp Kabel for "Structured Cabling Systems” meet the requirements in accordance with EIA/TIA-568 and TSB36, as well as ISO/IEC 11801 or EN 50173 (Class EA - permanent link).

Product Make-up

  • Solid conductor 4x2xAWG23/1
  • S/FTP: copper braid as overall screening and pair screening with aluminium compound foil
  • F/UTP: Foil shielding as overall shielding, 2 cores stranded to pair, 4 pairs stranded to bundle with central cross
  • F/FTP: aluminium compound foil as overall screening and pair screening
  • outer sheath either as PVC (grey RAL 7035) or LSZH (orange RAL 2003)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

Minimum bending radius

  • Fixed installation: 4 x outer diameter
  • during installation: 8 x outer diameter

Characteristic impedance

  • 100 Ω ± 15%

Temperature range

  • During installation: 0 °C to +50 °C
  • Fixed installation: -20°C to +60°C

  • Packaging size: Drum
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.