Article number Number of cores and mm² per conductor Outer diameter [mm] Copper index (kg/km) Weight (kg/km)
N2XH-O
1550556
1x1,5 RE 5.5 14 53
1550557
1x2,5 RE 5.8 24 58
3017600
1x4 RE 6.2 38 69
30017645
1x6 RE 6.5 58 90
30017646
1x10 RE 7.3 96 131
1550561
1x16 RE 8.6 154 197
30017648
1x25 RM 10.2 240 293
30017649
1x35 RM 11.3 336 389
30017650
1x50 RM 12.7 480 517
30017651
1x70 RM 14.6 672 717
30017652
1x95 RM 16.3 912 972
30017653
1x120 RM 18.3 1152 1215
3017601
1x150 RM 20.0 1440 1494
3017602
1x185 RM 22.6 1776 1855
3017603
1x240 RM 25.2 2304 2387
1112935
1x300 RM 27.9 2880 2971
30017654
2x1,5 RE 12.0 29 185
30017655
2x2,5 RE 13.0 48 220
30017656
2x4 RE 14.0 77 275
30017657
2x6 RE 15.0 115 335
30017658
2x10 RE 16.0 192 450
1550578
2x16 RE 18.0 307 625
3017605
2x25 RM 21.0 480 950
35002466
3x1,5 RE 8.9 43 125
1550581
3x2,5 RE 9.8 72 163
N2XH-J
1112940
1x25 RM 10.2 240 293
1112941
1x35 RM 11.3 336 389
1112942
1x50 RM 12.7 480 517
1112943
1x70 RM 14.6 672 717
1112944
1x95 RM 16.3 912 972
1112945
1x120 RM 18.3 1152 1215
1112946
1x150 RM 20.0 1440 1494
1112947
1x185 RM 22.6 1776 1855
1112948
1x240 RM 25.2 2304 2387
1112949
1x300 RM 27.9 2880 2971
30017659
3x1,5 RE 8.9 43 125
30017660
3x2,5 RE 9.8 72 163
30017661
3x4 RE 10.8 115 219
30017662
3x6 RE 11.8 173 289
30017663
3x10 RE 13.6 288 431
1550601
3x16 RE 16.7 461 638
30017665
3x25 RM 20.2 720 1015
1550603
3x35 SM 22.3 1080 1231
1550604
3x50 SM 25.5 1440 1652
1550605
3x70 SM 30.0 2016 2455
1550606
3x95 SM 32.0 2736 3260
1550607
3x120 SM 35.0 3456 4000
1550608
3x150 SM 39.0 4320 5100
1550609
3x185 SM 44.0 5328 6160
1550610
3x240 SM 49.0 6912 8000
30017671
4x1,5 RE 9.7 58 147
30017672
4x2,5 RE 10.6 96 195
30017673
4x4 RE 11.7 154 266
30017674
4x6 RE 12.9 230 355
30017675
4x10 RE 15.2 384 547
1550616
4x16 RE 18.3 614 839
30017677
4x25 RM 22.6 960 1294
1550618
4x35 SM 25.8 1344 1605
1550619
4x50 SM 29.4 1920 2154
1550620
4x70 SM 34.4 2688 3047
1550621
4x95 SM 38.6 3648 4102
1550622
4x120 SM 42.4 4608 5062
1550623
4x150 SM 47.2 5760 6256
1550624
4x185 SM 52.0 7104 7751
1550625
4x240 SM 58.6 9216 10047
30017683
5x1,5 RE 10.5 72 174
30017684
5x2,5 RE 11.5 120 233
30017685
5x4 RE 12.7 192 319
30017686
5x6 RE 14.2 288 437
30017687
5x10 RE 17.0 480 682
1550631
5x16 RE 20.2 768 1036
30017689
5x25 RM 24.9 1200 1584
1550633
5x35 RM 28.4 1680 2155
30017690
7x1,5 RE 11.3 101 214
30017691
7x2,5 RE 12.4 168 291
30017692
7x4 RE 17.0 269 540
3017612
10x1,5 RE 14.0 144 299
3017613
10x2,5 RE 15.8 240 419
30017693
12x1,5 RE 14.7 173 342
30017694
12x2,5 RE 16.4 288 480
3017614
12x4 RE 21.0 461 805
3017615
14x1,5 RE 17.0 202 480
3017616
14x2,5 RE 19.0 336 635
3017617
19x1,5 RE 18.0 274 600
3017618
19x2,5 RE 21.0 456 810
3017619
24x1,5 RE 20.2 346 625
3017620
24x2,5 RE 24.0 576 990
3017621
30x1,5 RE 21.3 432 738
3017622
30x2,5 RE 23.7 720 1045
1550649
3x50/25 SM 28.5 1680 2100
1550650
3x70/35 SM 31.4 2352 2800
1550651
3x95/50 SM 34.9 3216 3750
1550652
3x120/70 SM 38.0 4128 4750
1550653
3x150/70 SM 43.3 4992 5750
1550654
3x185/95 SM 47.2 6240 7200
1550655
3x240/120 SM 53.4 8064 9300

Application range

  • For installation on or under the plaster
  • Fixed installation indoor, in air or concrete
  • For buildings or industrial plants with a high density of people or valuable assets
  • No direct burial or installation in water
  • Outdoor laying only when protected from direct sunlight and other external impacts

Product features

  • Flame-retardant according IEC 60332-1-2
  • No flame-propagation according to IEC 60332-3-24
  • Halogen-free according to IEC 60754-1
    (amount of halogen acid gas)
    Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Low smoke density according to IEC 61034-2

Norm references / Approvals

  • HD 604/VDE 0276-604

Product Make-up

  • Bare copper wire conductor
  • Abbreviations "re", "rm", "se", "sm":
    r = round conductor form;
    s = sectorial conductor form;
    e = single-wire conductor;
    m = multi-wire conductor;
  • Core insulation: Cross-linked Polyethylen (XLPE)
  • Filling compound over the core assembly
  • Outer sheath: halogen-free, thermoplastic polyolefin compound

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

Core identification code

  • Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
  • From 6 cores: black with white numbers

Conductor stranding

  • Single or multi-wire

Minimum bending radius

  • Single-core: 15 x outer diameter
  • Multi-core: 12 x outer diameter

Nominal voltage

  • U0/U: 0.6/1.0 kV

Test voltage

  • 4000 V

Protective conductor

  • J = with GN-YE protective conductor
  • O = without protective conductor

Temperature range

  • During installation: -5°C bis +90°C
    Fixed installation: -40°C bis +90°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.