ÖLFLEX® HEAT 125 SC

VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements

ÖLFLEX® HEAT 125 SC - halogen free single core with GL certificate, special fire performance, IEC 60332-3, suitable for +125°C

  • CPR: Article number choice under www.lappkabel.com/cpr
  • VDE-tested and -marked
  • Improved characteristics in the event of a fire

Flame-retardant Halogen-free Cold-resistant Assembly time Temperature-resistant UV-resistant

CE VDE DNV EAC Fire

Article number Conductor cross-section (mm²) Outer diameter [mm] Core colour m/ring m/box Copper index (kg/km) Weight (kg/km)
ÖLFLEX® HEAT 125 SC - H05Z-K - U0/U: 300/500 V
1232000
0.5 2.2 green/yellow 100 - 4.8 8
1232001
0.5 2.2 black 100 - 4.8 8
1232002
0.5 2.2 blue 100 - 4.8 8
1232003
0.5 2.2 brown 100 - 4.8 8
1232005
0.5 2.2 yellow 100 - 4.8 8
1232006
0.5 2.2 green 100 - 4.8 8
1232007
0.5 2.2 violet 100 - 4.8 8
1232009
0.5 2.2 orange 100 - 4.8 8
1232104
0.5 2.2 red 100 - 4.8 8
1232105
0.5 2.2 white 100 - 4.8 8
1232106
0.5 2.2 grey 100 - 4.8 8
1232114
0.5 2.2 dark blue 100 - 4.8 8
1232001K
0.5 2.2 black - 3000 4.8 8
1233000
0.75 2.4 green/yellow 100 - 7.2 11
1233001
0.75 2.4 black 100 - 7.2 11
1233002
0.75 2.4 blue 100 - 7.2 11
1233003
0.75 2.4 brown 100 - 7.2 11
1233005
0.75 2.4 yellow 100 - 7.2 11
1233006
0.75 2.4 green 100 - 7.2 11
1233007
0.75 2.4 violet 100 - 7.2 11
1233009
0.75 2.4 orange 100 - 7.2 11
1233104
0.75 2.4 red 100 - 7.2 11
1233105
0.75 2.4 white 100 - 7.2 11
1233106
0.75 2.4 grey 100 - 7.2 11
1233114
0.75 2.4 dark blue 100 - 7.2 11
1233003K
0.75 2.4 brown - 2500 7.2 11
1233001K
0.75 2.4 black - 2500 7.2 11
1233106K
0.75 2.4 grey - 2500 7.2 11
1233002K
0.75 2.4 blue - 2500 7.2 11
1233009K
0.75 2.4 orange - 2500 7.2 11
1233114K
0.75 2.4 dark blue - 2500 7.2 11
1233105K
0.75 2.4 white - 2500 7.2 11
1233104K
0.75 2.4 red - 2500 7.2 11
1234000
1.0 2.5 green/yellow 100 - 9.6 14
1234001
1.0 2.5 black 100 - 9.6 14
1234002
1.0 2.5 blue 100 - 9.6 14
1234003
1.0 2.5 brown 100 - 9.6 14
1234005
1.0 2.5 yellow 100 - 9.6 14
1234006
1.0 2.5 green 100 - 9.6 14
1234007
1.0 2.5 violet 100 - 9.6 14
1234009
1.0 2.5 orange 100 - 9.6 14
1234104
1.0 2.5 red 100 - 9.6 14
1234105
1.0 2.5 white 100 - 9.6 14
1234106
1.0 2.5 grey 100 - 9.6 14
1234114
1.0 2.5 dark blue 100 - 9.6 14
1234003K
1.0 2.5 brown - 2500 9.6 14
1234001K
1.0 2.5 black - 2500 9.6 14
1234106K
1.0 2.5 grey - 2500 9.6 14
1234002K
1.0 2.5 blue - 2500 9.6 14
1234000K
1.0 2.5 green/yellow - 2500 9.6 14
1234009K
1.0 2.5 orange - 2500 9.6 14
1234114K
1.0 2.5 dark blue - 2500 9.6 14
1234105K
1.0 2.5 white - 2500 9.6 14
1234104K
1.0 2.5 red - 2500 9.6 14
ÖLFLEX® HEAT 125 SC - H07Z-K - U0/U: 450/750 V
1235000
1.5 3 green/yellow 100 - 14.4 21
1235001
1.5 3 black 100 - 14.4 21
1235002
1.5 3 blue 100 - 14.4 21
1235003
1.5 3 brown 100 - 14.4 21
1235005
1.5 3 yellow 100 - 14.4 21
1235006
1.5 3 green 100 - 14.4 21
1235007
1.5 3 violet 100 - 14.4 21
1235009
1.5 3 orange 100 - 14.4 21
1235104
1.5 3 red 100 - 14.4 21
1235105
1.5 3 white 100 - 14.4 21
1235106
1.5 3 grey 100 - 14.4 21
1235114
1.5 3 dark blue 100 - 14.4 21
1235003K
1.5 3 brown - 2000 14.4 21
1235001K
1.5 3 black - 2000 14.4 21
1235106K
1.5 3 grey - 2000 14.4 21
1235002K
1.5 3 blue - 2000 14.4 21
1235000K
1.5 3 green/yellow - 2000 14.4 21
1235009K
1.5 3 orange - 2000 14.4 21
1235114K
1.5 3 dark blue - 2000 14.4 21
1235105K
1.5 3 white - 2000 14.4 21
1235104K
1.5 3 red - 2000 14.4 21
1236000
2.5 3.6 green/yellow 100 - 24 33
1236001
2.5 3.6 black 100 - 24 33
1236002
2.5 3.6 blue 100 - 24 33
1236003
2.5 3.6 brown 100 - 24 33
1236005
2.5 3.6 yellow 100 - 24 33
1236006
2.5 3.6 green 100 - 24 33
1236007
2.5 3.6 violet 100 - 24 33
1236009
2.5 3.6 orange 100 - 24 33
1236104
2.5 3.6 red 100 - 24 33
1236105
2.5 3.6 white 100 - 24 33
1236106
2.5 3.6 grey 100 - 24 33
1236114
2.5 3.6 dark blue 100 - 24 33
1236001K
2.5 3.6 black - 1200 24 33
1237000
4.0 4.3 green/yellow 100 - 38.4 49
1237001
4.0 4.3 black 100 - 38.4 49
1237002
4.0 4.3 blue 100 - 38.4 49
1237003
4.0 4.3 brown 100 - 38.4 49
1237009
4.0 4.3 orange 100 - 38.4 49
1237104
4.0 4.3 red 100 - 38.4 49
1237105
4.0 4.3 white 100 - 38.4 49
1237106
4.0 4.3 grey 100 - 38.4 49
1237114
4.0 4.3 dark blue 100 - 38.4 49
1238000
6.0 4.8 green/yellow 100 - 57.6 67
1238001
6.0 4.8 black 100 - 57.6 67
1238002
6.0 4.8 blue 100 - 57.6 67
1238003
6.0 4.8 brown 100 - 57.6 67
1238104
6.0 4.8 red 100 - 57.6 67
1238106
6.0 4.8 grey 100 - 57.6 67
1238114
6.0 4.8 dark blue 100 - 57.6 67
1239000
10.0 6.2 green/yellow 100 - 96 112
1239001
10.0 6.2 black 100 - 96 112
1239002
10.0 6.2 blue 100 - 96 112
1239003
10.0 6.2 brown 100 - 96 112
1239104
10.0 6.2 red 100 - 96 112
1240000
16.0 7.2 green/yellow 100 - 153.6 172
1240001
16.0 7.2 black 100 - 153.6 172
1240002
16.0 7.2 blue 100 - 153.6 172
1240003
16.0 7.2 brown 100 - 153.6 172
1240104
16.0 7.2 red 100 - 153.6 172
1240114
16.0 7.2 dark blue 100 - 153.6 172
1241000
25.0 8.9 green/yellow 100 - 240 262
1241001
25.0 8.9 black 100 - 240 262
1242000
35.0 10.1 green/yellow 100 - 336 362
1242001
35.0 10.1 black 100 - 336 362
1243000
50.0 12.5 green/yellow 100 - 480 512
1243001
50.0 12.5 black 100 - 480 512
1244000
70.0 14.2 green/yellow 100 - 672 710
1244001
70.0 14.2 black 100 - 672 710
1245000
95.0 16.6 green/yellow 100 - 912 937
1245001
95.0 16.6 black 100 - 912 937
1246001
120.0 18.2 black 100 - 1152 1159
1247000
150.0 20.6 green/yellow 100 - 1440 1447
1247001
150.0 20.6 black 100 - 1440 1447
1248001
185.0 22.5 black 100 - 1776 1790
1249001
240.0 26.4 black 100 - 2304 2318

Benefits

  • For safety in areas with high density of people
  • Reduction of flame propagation, density and toxicity of smoke gases in event of fire
  • Minimises damage to buildings and equipment caused by the formation of toxic acid fumes in fires
  • Certified for maritime applications

Application range

  • For the wiring and connection of lighting, heating appliances, control cabinets, and distributors in mechanical and plant engineering
  • For installation in tubes, on, in and under plaster as well as in closed installation ducts
  • Coil winding, electromagnets, pumps, electrical systems
  • Heat treatment plants, pressure die casting, heating and cooling technology
  • Suitable for assembling cable harnesses and wiring during switch cabinet installation

Product features

  • Fire behaviour:
    - Flame-retardant (IEC 60332-1-2)
    - Halogen-free (IEC 60754-1)
    - No corrosive gases (IEC 60754-2)
    - Low smoke density (IEC 61034-2)
    - Low toxicity (EN 50305)
  • Extended fire behaviour:
    H05Z-K (0,5mm² up to 1,0mm²):
    see data sheet
    H07Z-K (≥ 1,5mm²):
    no fire propagation according to IEC 60332-3-24 respectively IEC 60332-3-25
  • Oil-resistant according to DIN EN 50290-2-22 (TM54)
  • Abrasion and notch-resistant
  • UV-resistant according to ISO 4892-2, method A, and ozone resistant acc. to EN 50396 resp. VDE 0473-396, method B

Norm references / Approvals

  • Type H05Z-K and H07Z-K according to EN 50525-3-41 with advanced features
  • DNV GL certificate no. TAE00003NF

Product Make-up

  • Fine-wire, tinned-copper conductor
  • Electron beam cross-linked polyolefin copolymer insulation

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000993
  • ETIM 5.0 Class-Description: Single core cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000993
  • ETIM 6.0 Class-Description: Single core cable

Conductor stranding

  • Fine wire acc. to VDE 0295, class 5 / IEC 60228 class 5 from 0.5 mm²

Minimum bending radius

  • Fixed installation: 4 x outer diameter

Nominal voltage

  • Up to 1.0mm² U0/U 300/500 V
    From 1.5mm² U0/U 450/750 V
  • 0.6/1kV from 1.5 mm² in the case of fixed and protected installation

Test voltage

  • 4000 V

Temperature range

  • Fixed installation: -55°C to +125°C
    Temporary (3.000h): up to +145°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.