UNITRONIC® FD Li2YCY (TP) A BE

Shielded, low-capacitance, twisted-pair PE/PVC data cable for power chain/cable carrier, UL AWM for USA+CAN

UNITRONIC® FD Li2YCY (TP) A B: Shielded, low-capacitance, twisted-pair PVC signal/data cable for power chain/cable carrier, UL AWM for USA and Canada

  • Better priced than UNITRONIC® FD CP (TP) plus
  • Low capacitance, AWM by UL for USA+CAN
  • UNITRONIC® FD Li2YCY (TP) A BE: DIN 47100, refer to Appendix T9

Mechanical and plant engineeringSuitable for outdoor useFlame-retardantOil-resistantPower chainInterference signalsUV-resistant

CERUC_RU

Article number Dimension and cross section in mm2Outer diameter [mm]Copper index [kg/km]Weight [kg/km]
0031377
1 x 2 x 0.144.311.223
0031378
2 x 2 x 0.145.919.442
0031379
3 x 2 x 0.146.223.447
0031380
4 x 2 x 0.146.727.157
0031381
5 x 2 x 0.147.337.468
0031382
6 x 2 x 0.147.549.486
0031383
8 x 2 x 0.148.854.8109
0031384
10 x 2 x 0.1410.160.1120
0031385
12 x 2 x 0.149.861.6150
0031386
1 x 2 x 0.254.714.927
0031387
2 x 2 x 0.256.63257
0031388
3 x 2 x 0.25738.472
0031389
4 x 2 x 0.257.643.285
0031390
5 x 2 x 0.258.551.592
0031391
6 x 2 x 0.258.871.8114
0031392
8 x 2 x 0.2510.374.4145
0031393
10 x 2 x 0.2511.890182
0031394
14 x 2 x 0.2512111.2213
0031395
25 x 2 x 0.2516.3310310
0031396
1 x 2 x 0.345.118.136
0031397
2 x 2 x 0.347.34169
0031398
3 x 2 x 0.3485293
0031399
4 x 2 x 0.348.759106
0031400
5 x 2 x 0.349.767136
0031401
6 x 2 x 0.341086.2165
0031402
8 x 2 x 0.3411.8107.5221
0031403
10 x 2 x 0.3413.7131.1274
0031404
1 x 2 x 0.55.52347
0031405
2 x 2 x 0.58.35099
0031406
3 x 2 x 0.58.871.8120
0031407
4 x 2 x 0.59.874.4130
0031408
5 x 2 x 0.510.784.5164
0031409
6 x 2 x 0.511.399.6182
0031410
8 x 2 x 0.513.2144.3278
0031411
10 x 2 x 0.515.2176325
0031412
14 x 2 x 0.515.5215.4401
0031413
1 x 2 x 0.755.93561
0031414
2 x 2 x 0.75960104
0031415
3 x 2 x 0.759.885.7148
0031416
4 x 2 x 0.7510.793.6167
0031417
5 x 2 x 0.7511.9115202
0031418
6 x 2 x 0.7512.3130.4233
0031419
8 x 2 x 0.7514.7192.2330
0031420
10 x 2 x 0.7516.7258390
0031421
14 x 2 x 0.7517316.6515
0031422
1 x 2 x 1.06.34271
0031423
2 x 2 x 1.09.973126
0031424
3 x 2 x 1.010.593.6167
0031425
4 x 2 x 1.011.8117.8213
0031426
5 x 2 x 1.013.1139247

Benefits

  • Improved transmission characteristics thanks to low-capacitance core insulation and twisted pairs
  • Cable specification optimized for use in power chain/cable carrier in the USA, on the basis of NFPA 79, Section 12.9.2

Application range

  • Suitable for use in measuring, control and regulating circuits
  • Linear robots, automated handling equipment
  • Use in drag chain/cable carrier/power track - in case of horizontal installation travel distances up to 50 m
  • For use in chain/carrier: Please respect the assembly guidelines listed in Appendix T3

Product features

  • Low capacitance
  • EMC optimized thanks to overall copper braid shielding
  • Flexibility for use inside power chain/cable carrier
  • Oil-resistant according to DIN EN 50290-2-22 (TM54)
  • Flame-retardant acc. to IEC 60332-1-2,
    UL VW-1, Cable Flame Test, CSA FT 1

Norm references / Approvals

  • Based on VDE 0812
  • UL AWM Style 2570 80°C 1000V (external interconnection) for USA (UL File No.: E63634) and in line with NFPA 79, Section 12.9.2
  • AWM I/II A/B 80°C 1000V acc. to CSA C22.2 No. 210-15 and certified by UL (cRU) for Canada
  • EU conformity and mark with regard to the European RoHS Directive

Product Make-up

  • Flexible conductor made of bare copper strands
  • Low-capacitance PE core insulation
  • Non-woven wrapping
  • Tinned-copper braiding
  • Outer sheath made of PVC
    Outer sheath colour: black (similar to RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Core identification code

  • UNITRONIC®
    FD Li2YCY (TP) A BE:
  • DIN 47100, refer to Appendix T9

Mutual capacitance

  • Up to 0.5 mm²: 60 nF/km
  • Up to 1.0 mm²: 70 nF/km

Inductivity

  • approx. 0.65 mH/km

Conductor stranding

  • Fine wire
  • From 0.5 mm²: Finest wire/Conductor class 6 acc. to IEC 60228

Minimum bending radius

  • Flexing: 7.5 x outer diameter
  • Fixed installation: 4 x outer diameter

Loop resistance

  • Ohmic (DC) and loop/bidirectional @ 20 °C
  • 0.14 mm² (26 AWG): 276.0 Ω∕km;
    0.25 mm² (24 AWG): 158.0 Ω∕km;
    0.34 mm² (22 AWG): 110.8 Ω∕km;
    0.5 mm² (21 AWG): 78.0 Ω∕km;
    0.75 mm² (19 AWG): 52.0 Ω∕km;
    1 mm² (18 AWG): 39.0 Ω∕km

Temperature range

  • Flexing:
    VDE: -5 °C to 70 °C
    UL AWM: -5 °C to 80 °C
  • Stationary use:
    VDE: -40 °C to 70 °C
    UL AWM: -5 °C to 80 °C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.