UNITRONIC® Li2YCYv (TP)

Shielded data cable with PE core insulation, reinforced outer sheath and twisted in pairs

UNITRONIC® Li2YCYv (TP) - shielded PVC data cable in twisted pairs, with black, reinforced sheath suitable for outdoor installation

Cables for RS485/RS422

Interference signals

Article number Number of pairs and mm² per conductor Outer diameter [mm] Copper index (kg/km) Weight (kg/km)
UNITRONIC® Li2YCYv (TP) black for outdoor installation and direct burial, 7-wire
0031350
2 x 2 x 0.22 8.1 24.2 79
0031351
3 x 2 x 0.22 8.7 28.6 93
0031352
4 x 2 x 0.22 8.9 34.2 100
0031353
8 x 2 x 0.22 10.7 70 156
0031354
10 x 2 x 0.22 12 76 185
0031365
1 x 2 x 0.34 7.4 20 69
0031355
2 x 2 x 0.34 9.3 34.1 102
0031356
3 x 2 x 0.34 10 43 117
0031357
4 x 2 x 0.34 10.3 52.8 130
0031358
8 x 2 x 0.34 12.6 85.8 206
0031366
1 x 2 x 0.5 7.9 29 79
0031360
2 x 2 x 0.5 10.1 37 120
0031361
3 x 2 x 0.5 10.9 55 142
0031362
4 x 2 x 0.5 11.2 60 160
0031363
8 x 2 x 0.5 13.9 113.3 251
0031364
10 x 2 x 0.5 16 148 303

Benefits

  • 7-wire braided conductor (UNITRONIC® Li2YCY (TP) and UNITRONIC® Li2YCYv (TP)) can be used for Maxi TERMI-POINT® wiring
  • Overall shield minimises electrical
    interference
  • Decoupling of circuits by means of
    twisted-pair (TP) design (crosstalk effects)

Application range

  • Particularly suitable for wiring data systems with transmission rates up to 10 megabits per second, and is suitable for the RS422 and RS485 interfaces.
  • For fixed and limited flexible installation
  • Can be used in dry or damp rooms
  • Signal, control and measuring cable, for transmission of weak, sensitive signals and high bit rates
  • UNITRONIC®
    Li2YCYv (TP) with its reinforced, nominal/ minimum average wall thickness of at least 1.8 mm of the black outer sheath (Yv) is designed for indoor and outdoor use as well as for applications where a reinforced outer sheath may turn out to be advantageous

Product features

  • Flame-retardant according to IEC 60332-1-2

Norm references / approvals

  • Based on VDE 0812

Design

  • 7-wire strand made of bare copper wires
  • Core insulation made of polyethylene (PE)
  • Twisted pair (TP) structure
  • Tin-plated copper braiding
  • Outer sheath made of PVC
    Outer sheath colour: pebble grey (RAL 7032)
  • Wall thickness of the outer sheath is increased/reinforced ("Yv")
  • Outer sheath colour: black (RAL 9005)

Classification

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Core identification code

  • DIN 47100, refer to appendix T9

Operating capacitance

  • At 800 Hz: max. 60 nF/km

Peak operating voltage

  • (not for power applications)
    250 V

Inductance

  • approx. 0.65 mH/km

Conductor design

  • Stranded wire, based on VDE 0881, 7-wire

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 6 x outer diameter

Short-range crosstalk attenuation

  • Up to 1 MHz min. 50 dB
  • Up to 10 MHz min. 40 dB

Test voltage

  • Core/Core: 2000 V
  • Core/Shield: 1000 V

Characteristic impedance

  • 100 ±15 ohm (> 1 MHz)

Temperature range

  • Occasional flexing: -5°C to +70°C
  • Fixed installation: -40°C to +80°C

Unless otherwise specified, the product values shown are nominal values. You can receive further values, such as tolerances, upon request if they available and have been released for publication.
Copper price basis: EUR 150/100 kg; see catalogue appendix T17 for the application and definition of "Metal price basis" and "Metal index"
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging: Ring ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred packaging (e.g. 1 x 500 m drum or 5 x 100 m rings)
Photographs are not to scale and do not represent detailed images of the respective products.