ÖLFLEX® CLASSIC 128 H BK 0,6/1 kV

Cost-effective halogen-free control cable with improved fire characteristics, 0,6/1kV

ÖLFLEX® CLASSIC 128 H BK 0,6/1 kV Power and Control Cable, halogen-free/ highly flame retardant, HFFR, flexible, conductor class 5, public buildings

  • For space-saving and cost-effective installation
  • For use within public buildings and industrial plants
  • UV and weather-resistant according to ISO 4892-2

Suitable for outdoor useFlame-retardantHalogen-freeUV-resistant

CE

Article number Number of cores and mm² per conductorOuter diameter [mm]Copper index (kg/km)Weight (kg/km)
1123520
2 X 1.07.419.276
1123521
3 G 1.07.828.8101
1123522
4 G 1.08.438.4120
1123523
5 G 1.09.248143
1123524
7 G 1.09.967.2179
1123525
12 G 1.012.8115.2283
1123528
2 X 1.58.428.8112
1123529
3 G 1.58.943.2135
1123530
4 G 1.59.657.6163
1123531
5 G 1.510.572196
1123532
7 G 1.511.4100.8253
1123533
12 G 1.515.1172.8396
1123534
18 G 1.518.0259.2589
1123535
25 G 1.521.1360801
1123537
3 G 2.510.172189
1123538
4 G 2.511.096232
1123539
5 G 2.512.1120279
1123541
12 G 2.517.9288603
1123544
3 G 4.011.4115.2260
1123545
4 G 4.012.5153.6322
1123546
5 G 4.013.7192387
1123548
4 G 6.013.9230.4431
1123549
5 G 6.015.8288533
1123550
4 G 10.017.9384734
1123553
4 G 25.025.29601617

Benefits

  • Space-saving installation due to small cable diameters
  • Easy handling and installation due to flexible design

Application range

  • Public buildings
  • Plant engineering
    Industrial machinery
    Heating and air-conditioning systems
  • Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards
  • Suitable for outdoor applications

Product features

  • Flame-retardant according to IEC 60332-1-2
    (flame spread on a single cable)
  • No flame-propagation according to IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)
  • Halogen-free according to IEC 60754-1
    (amount of halogen acid gas)
    Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Low smoke density according to IEC 61034-2
  • UV and weather-resistant according to ISO 4892-2
  • Ozone-resistant according to EN 50396

Norm references / Approvals

  • Based on EN 50525-3-11

Product Make-up

  • Fine-wire strand made of bare copper wires
  • Core insulation: Halogen-free
  • Outer sheath made of special halogen-free coumpound, black

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

Core identification code

  • Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
  • From 6 cores: black with white numbers

Conductor stranding

  • Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 4 x outer diameter

Nominal voltage

  • U0/U: 600/1000 V

Test voltage

  • 4000 V

Protective conductor

  • G = with GN-YE protective conductor
  • X = without protective conductor

Temperature range

  • Occasional flexing: -5°C to +70°C
  • Fixed installation: -40°C to +80°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.