UNITRONIC® FD Li2YCY (TP) A BA

Shielded, low-capacitance, twisted-pair PE/PVC data cable for power chain/cable carrier, UL AWM for USA+CAN

UNITRONIC® FD Li2YCY (TP) A B: Shielded, low-capacitance, twisted-pair PVC signal/data cable for power chain/cable carrier, UL AWM for USA and Canada

  • Better priced than UNITRONIC® FD CP (TP) plus
  • Low capacitance, AWM by UL for USA+CAN
  • UNITRONIC® FD Li2YCY (TP) A BA: North-American Core Identification Colors

Mechanical and plant engineeringSuitable for outdoor useFlame-retardantOil-resistantPower chainInterference signalsUV-resistant

CERUC_RU

Article number Number of pairs and mm² per conductorOuter diameter [mm]Copper index (kg/km)Weight (kg/km)
0031431
5 x 2 x 0.147.337.468

Benefits

  • Improved transmission characteristics thanks to low-capacitance core insulation and twisted pairs
  • Cable specification optimized for use in power chain/cable carrier in the USA, on the basis of NFPA 79, Section 12.9.2

Application range

  • Suitable for use in measuring, control and regulating circuits
  • Linear robots, automated handling equipment
  • Use in drag chain/cable carrier/power track - in case of horizontal installation travel distances up to 50 m
  • For use in chain/carrier: Please respect the assembly guidelines listed in Appendix T3

Product features

  • Low capacitance
  • EMC optimized thanks to overall copper braid shielding
  • Flexibility for use inside power chain/cable carrier
  • Oil-resistant according to DIN EN 50290-2-22 (TM54)
  • Flame-retardant acc. to IEC 60332-1-2,
    UL VW-1, Cable Flame Test, CSA FT 1

Norm references / Approvals

  • Based on VDE 0812
  • UL AWM Style 2570 80°C 1000V (external interconnection) for USA (UL File No.: E63634) and in line with NFPA 79, Section 12.9.2
  • AWM I/II A/B 80°C 1000V acc. to CSA C22.2 No. 210-15 and certified by UL (cRU) for Canada
  • EU conformity and mark with regard to the European RoHS Directive

Product Make-up

  • Flexible conductor made of bare copper strands
  • Low-capacitance PE core insulation
  • Non-woven wrapping
  • Tinned-copper braiding
  • Outer sheath made of PVC
    Outer sheath colour: black (similar to RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Core identification code

  • UNITRONIC®
    FD Li2YCY (TP) A BA:
  • - Pair 01: Black, Red;
    - Pair 02: Black, White;
    - Pair 03: Black, Green;
    - Pair 04: Black, Blue;
    - Pair 05: Black, Yellow;
    - Pair 06: Black, Brown;
    - Pair 07: Black, Orange;
    - Pair 08: Red, White;
    - Pair 09: Red, Green;
    - Pair 10: Red, Blue;
    - Pair 11: Red, Yellow;
    - Pair 12: Red, Brown;
    - Pair 13: Red, Orange;
    - Pair 14: Green, White;
    - Pair 15: Green, Blue;
    - Pair 16: Green, Yellow;
    - Pair 17: Green, Brown;
    - Pair 18: Green, Orange;
    - Pair 19: White, Blue;
    - Pair 20: White, Yellow;
    - Pair 21: White, Brown;
    - Pair 22: White, Orange;
    - Pair 23: Blue, Yellow;
    - Pair 24: Blue, Brown;
    - Pair 25: Blue, Orange;
    - Exception Single-paired/24 - 22 AWG: Black, White

Mutual capacitance

  • Up to 0.5 mm²: 60 nF/km
  • Up to 1.0 mm²: 70 nF/km

Inductivity

  • approx. 0.65 mH/km

Conductor stranding

  • Fine wire
  • From 0.5 mm²: Finest wire/Conductor class 6 acc. to IEC 60228

Minimum bending radius

  • Flexing: 7.5 x outer diameter
  • Fixed installation: 4 x outer diameter

Loop resistance

  • Ohmic (DC) and loop/bidirectional @ 20 °C
  • 0.14 mm² (26 AWG): 276.0 Ω∕km;
    0.25 mm² (24 AWG): 158.0 Ω∕km;
    0.34 mm² (22 AWG): 110.8 Ω∕km;
    0.5 mm² (21 AWG): 78.0 Ω∕km;
    0.75 mm² (19 AWG): 52.0 Ω∕km;
    1 mm² (18 AWG): 39.0 Ω∕km

Temperature range

  • Flexing:
    VDE: -5 °C to 70 °C
    UL AWM: -5 °C to 80 °C
  • Stationary use:
    VDE: -40 °C to 70 °C
    UL AWM: -5 °C to 80 °C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.