NA2XS2Y

PE medium voltage cable with aluminium conductor

NA2XS2Y, VDE, PE medium voltage cable acc. VDE 0276-620, with aluminium conductor, for fixed installation

  • 3 voltage classes: 6/10 (12) kV, 12/20 (24) kV, 18/30 (36) kV
  • With aluminium conductor

Suitable for outdoor useMechanical resistanceUV-resistant

VDE

Article number Number of cores and mm² per conductorOuter diameter [mm]Copper index (kg/km)Weight (kg/km)
6/10 (12) kV
38107886
1x50 RM/1625182617
38107887
1x70 RM/1626182701
38107888
1x95 RM/1628182805
38107889
1x120 RM/1630182900
32702886
1X150 RM/25312831081
38107890
1x185 RM/25332831215
32702885
1X240 RM/25352831414
38107891
1x300 RM/25372831614
38107892
1x400 RM/35413942022
38105313
1X500 RM/35433942367
38107893
1x630 RM/35473942815
12/20 (24) kV
38107894
1x35 RM/1628182700
32701312
1X50 RM/1629182767
38107895
1x70 RM/1631182860
38107896
1x70 RM/2531283950
38000020
1X95 RM/1632182974
1552075
1X120 RM/16341821078
30018695
1X150 RM/25352831267
38106595
1X185 RM/25372831412
38106519
1X240 RM/25392831625
38107897
1x300 RM/25412831839
3033789
1X400 RM/35443942224
38107898
1x500 RM/35473942597
1550993
1X630 RM/35503943281
1552072
1X800 RM/35563943983
18/30 (36) kV
38107899
1x50 RM/1634182980
38107900
1x70 RM/16361821083
38107901
1x95 RM/16371821209
38107902
1x120 RM/16391821324
38107903
1x150 RM/25402831522
38107904
1x185 RM/25422831680
38107905
1x240 RM/25442831910
38107906
1x300 RM/25462832141
38107907
1x400 RM/35493942547
38107908
1x500 RM/35523942956
38107909
1x630 RM/35563943465

Application range

  • Power and control cable for fixed installation in the following applications:
  • In water, in ground, outdoors and indoors
  • In cable trays for power stations, industry, and distribution networks
  • Burial without additional, suitable underground protection according to HD 620/VDE 0276-620 - Part 10-C (point 4): normal minimum installation depth 0.6 m, but at least 0.8 m under roads

Product features

  • Suitable for installation or operation under high mechanical stress due to the PE-sheath
  • Current rating according to HD 620/VDE 0276-620, Part 10-C, Table 7 (buried at +20 °C ground temperature according to HD 620/VDE 0276-620, Part 10-C, point 5) for routing underground and Table 8 (in the air at an air temperature of +30 °C according to HD 620/VDE 0276-620, Part 10-C, point 5) when used outdoors; but always taking into consideration corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the catalogue appendix T12) for installation in and on buildings

Norm references / Approvals

  • HD 620/ VDE 0276-620

Product Make-up

  • Aluminium conductor
  • Abbreviation "rm":
    r = round conductor form;
    m = multi-wire conductor
  • Core insulation: Cross-linked Polyethylen (XLPE)
  • Screen made of copper wires with one or two copper bond counter spiral
  • Outer sheath: PE, black

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC001140
  • ETIM 5.0 Class-Description: Medium voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC001140
  • ETIM 6.0 Class-Description: Medium voltage power cable

Conductor stranding

  • Multi-wire

Minimum bending radius

  • Fixed installation: 15 x outer diameter

Nominal voltage

  • U0/U: 6/10 (12) kV, 12/20 (24) kV, 18/30 (36) kV

Test voltage

  • Depending on nominal voltage:
    6/10 kV: 15 kV
    12/20 kV: 30 kV
    18/30 kV: 45 kV

Temperature range

  • During installation: -40°C to +70°C
  • Fixed installation: -40°C to +90°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Aluminium price basis: excludes aluminium. Refer to catalogue appendix T17 for the application and definition of "Metal price basis" and "Metal index".
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • * Trade product, no Lapp product
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.