NA2XS2Y

PE medium voltage cable with aluminium conductor

NA2XS2Y, VDE, PE medium voltage cable acc. VDE 0276-620, with aluminium conductor, for fixed installation

  • 3 voltage classes: 6/10 kV, 12/20 kV, 18/30 kV
  • With aluminium conductor

Suitable for outdoor use Mechanical resistance UV-resistant

VDE

Article number Number of cores and mm² per conductor Outer diameter [mm] Copper index (kg/km) Weight (kg/km)
6/10 kV
38107886
1x50 RM/16 25 182 617
38107887
1x70 RM/16 26 182 701
38107888
1x95 RM/16 28 182 805
38107889
1x120 RM/16 30 182 900
32702886
1X150 RM/25 31 283 1081
38107890
1x185 RM/25 33 283 1215
32702885
1X240 RM/25 35 283 1414
38107891
1x300 RM/25 37 283 1614
38107892
1x400 RM/35 41 394 2022
38105313
1X500 RM/35 43 394 2367
38107893
1x630 RM/35 47 394 2815
12/20 kV
38107894
1x35 RM/16 28 182 700
32701312
1X50 RM/16 29 182 767
38107895
1x70 RM/16 31 182 860
38107896
1x70 RM/25 31 283 950
38000020
1X95 RM/16 32 182 974
1552075
1X120 RM/16 34 182 1078
30018695
1X150 RM/25 35 283 1267
38106595
1X185 RM/25 37 283 1412
38106519
1X240 RM/25 39 283 1625
38107897
1x300 RM/25 41 283 1839
3033789
1X400 RM/35 44 394 2224
38107898
1x500 RM/35 47 394 2597
1550993
1X630 RM/35 50 394 3281
1552072
1X800 RM/35 56 394 3983
18/30 kV
38107899
1x50 RM/16 34 182 980
38107900
1x70 RM/16 36 182 1083
38107901
1x95 RM/16 37 182 1209
38107902
1x120 RM/16 39 182 1324
38107903
1x150 RM/25 40 283 1522
38107904
1x185 RM/25 42 283 1680
38107905
1x240 RM/25 44 283 1910
38107906
1x300 RM/25 46 283 2141
38107907
1x400 RM/35 49 394 2547
38107908
1x500 RM/35 52 394 2956
38107909
1x630 RM/35 56 394 3465

Application range

  • Power and control cable for fixed installation in the following applications:
  • In water, in ground, outdoors and indoors
  • In cable trays for power stations, industry, and distribution networks
  • Burial without additional, suitable underground protection according to HD 620/VDE 0276-620 - Part 10-C (point 4): normal minimum installation depth 0.6 m, but at least 0.8 m under roads

Product features

  • Suitable for installation or operation under high mechanical stress due to the PE-sheath
  • Current rating according to HD 620/VDE 0276-620, Part 10-C, Table 7 (buried at +20 °C ground temperature according to HD 620/VDE 0276-620, Part 10-C, point 5) for routing underground and Table 8 (in the air at an air temperature of +30 °C according to HD 620/VDE 0276-620, Part 10-C, point 5) when used outdoors; but always taking into consideration corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the catalogue appendix T12) for installation in and on buildings

Norm references / Approvals

  • HD 620/ VDE 0276-620

Product Make-up

  • Aluminium conductor
  • Abbreviation "rm":
    r = round conductor form;
    m = multi-wire conductor
  • Core insulation: Cross-linked Polyethylen (XLPE)
  • Screen made of copper wires with one or two copper bond counter spiral
  • Outer sheath: PE, black

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC001140
  • ETIM 5.0 Class-Description: Medium voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC001140
  • ETIM 6.0 Class-Description: Medium voltage power cable

Conductor stranding

  • Multi-wire

Minimum bending radius

  • Fixed installation: 15 x outer diameter

Nominal voltage

  • U0/U: 6/10 kV, 12/20 kV, 18/30 kV

Test voltage

  • Depending on nominal voltage:
    6/10 kV: 15 kV
    12/20 kV: 30 kV
    18/30 kV: 45 kV

Temperature range

  • During installation: -20°C to +50°C
  • Fixed installation: -40°C to +90°C

  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.
  • Aluminium price basis: excludes aluminium. Refer to catalogue appendix T17 for the application and definition of "Metal price basis" and "Metal index".
  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.